The CPMP-4 version of the IR Free DC Coupon CPMP series incorporates moisture-wicking material and our patent pending engineered STABLE backfill that significantly improves accuracy, durability and usability.
Suitable for use with both new build and existing structures, the CPMP is installed adjacent to the protected structure and contains an encased permanent internal reference electrode positioned to sense the true carbon steel coupon potential.
This innovative design shields the reference electrode from external interference, allowing for highly accurate measurements of the coupon potential and polarization decay even while the coupon is connected to an active CP system.
When used in conjunction with the Corrosion Service ZRA (zero resistance ammeter), the CPMP provides a direct measurement of cathodic protection current density and further validation of corrosion prevention system operation.
The CPMP-4 is ready to install off the shelf and does not require complicated installation procedures in the field.
Features
Validates corrosion prevention system operation on buried/immersed infrastructure
Reduces operating costs by eliminating the need to interrupt foreign sources of interference
Allows confirmation of actual versus design operating parameters
Includes industry first engineered STABLE zinc backfill
Integrated zinc permanent reference electrode
Moisture wicking materials that improve soil contact
Easy hydro-vac or hand excavation for installation in native backfill
Compatible with remote monitoring and data recording hardware