Corrosion Service
IR Free DC Coupon (CPMP-4)
SKU: CPMP41005
Model CPMP-4 for permanent burial - with STABLE backfill.
The CPMP-4 IR-Free DC Coupon is designed to validate corrosion prevention system operation on buried or immersed infrastructure. Its integrated permanent zinc reference electrode is positioned to measure the true carbon steel coupon potential while shielding the reference electrode from external interference, supporting accurate potential and polarization decay measurements even when connected to an active cathodic protection system. The CPMP-4 incorporates moisture-wicking materials and Corrosion Service’s patent-pending engineered STABLE backfill to improve measurement accuracy, durability, and usability without requiring complicated mixing procedures in the field.
Product variants: 10 cm² / 5 m
Volume discounts are available for qualifying bulk orders. Use the Request Quote button to receive customized pricing.
Key Benefits
- Validate cathodic protection performance: Obtain reliable operating data to confirm actual versus design parameters and assess infrastructure protection.
- Improve measurement accuracy: The integrated reference electrode is shielded from external interference, supporting accurate potential and polarization decay measurements.
- Reduce operating costs: Assess corrosion protection without needing to interrupt foreign sources of interference.
- Simplify field installation: Ready to install with engineered STABLE backfill, eliminating complicated field mixing procedures.
- Support current density measurements: When used with a Corrosion Service Zero Resistance Ammeter (ZRA), the coupon provides direct measurement of cathodic protection current density.
Specifications
- Coupon type: IR-Free DC Coupon
- Coupon material: Carbon steel
- Coupon sizes: 10 cm² and 50 cm²
- Backfill: Patent-pending engineered STABLE backfill
- Reference electrode: Integrated permanent zinc reference electrode
- Additional design features: Moisture-wicking materials, serialized construction for traceability
- Installation: Adjacent to the protected structure in native backfill; suitable for hand or hydro-vac excavation
- Compatibility: Remote monitoring and data recording hardware; compatible with Corrosion Service ZRA for current density measurements
- Applications: New and existing buried or immersed infrastructure
Downloads
Shipping & Returns
Shipping costs and delivery timelines vary by order. All returns require prior written approval and may be subject to a restocking fee.
Please review our Terms & Conditions for complete shipping, return, and warranty details.
Coupon Area: 10 cm², Cable Length: 5 m